ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. aqf120u-5s aqf120u-12s aqf120u-15s aqf120u-24s aqf120u-48s max output wattage (w) 150 w (30cfm fan) 180 w (18cfm fan) max output wattage (w) 120 w voltage 90-264 vac or 120-370 vdc (80-274 vac or 110-390 vdc with derating) frequency (hz) 47-63 hz current (full load) <2.0 a max. (115 vac) / <1.0 a max. (230 vac) inrush current (<2ms) < 30 a max. (115 vac) / < 60 a max. (230 vac) leakage current < 0.5 ma max. input power factor pf>0.99 (115 vac) / pf>0.95 (230 vac) at full load voltage (v.dc.) 5v 12v 15v 24v 48v voltage accuracy 2% voltage adj. range (v.dc) 4.7~5.3v 11.4~13.2v 13.5~16v 22.8~26.4v 45.6~52v current (18/30 cfm fan)(a) max 0~30 (30cfm fan) 0~15 (18cfm fan) 0~12 (18cfm fan) 0~7.5 (18cfm fan) 0~3.75 (18cfm fan) current (convection) (a) max 0~24 0~10 0~8 0~5 0~2.5 line regulation 1% load regulation 1% minimum load 5% 1% maximum capacitive load 100,000 f 40,000f 35,000f 20,000f 1,200f ripple & noise (max.) 100mv 50mv 50mv 100mv 200mv efficiency (typ.) 87% 90% 90% 93% 93% output hold-up time 15 ms min. over power protection auto recovery over voltage protection auto recovery ( > 125% vout) protection short circuit protection auto recovery input-output (v.ac) 4000vac or 5656vdc input-fg (v.ac) 2000v isolation output-fg . (v.ac) 500v operating temperature -25c?+70c (with derating) storage temperature -25c?+85c temperature coefficient 0.03%/c ( 0~50c ) humidity 95% rh mtbf >120,000 h @ 25c (mil-hdbk-217f, notice 1) environment vibration 10~500hz, 2g 10min./1cycle, 60min. each along x, y, z axes. dimension (l x w x h) 5.0 x 3.24 x 1.5 inches ( 127.0 x 82.2 x 38.1 mm ) tolerance ? 0.5 mm weight 382 g physical cooling method free convection / 18 cfm fan safety agency approvals ce, ul60950-1(exc ept 5s / 15s), cb(except 5s / 15s) emi (conducted & radiated emission) en61000-6-3 en 55022 class b emc ems (noise immunity) en 55024 key features ? u bracket switching power supply ? 180 watt with 18cfm fan for 12v to 48v output voltage ? 150 watt with 30cfm fan for 5v output voltage ? high efficiency up to 93% ? universal input: 90-264 vac ? low ripple and noise ? with p.f.c. function >0.95 ? 120 watt with free air convection ? ultra compact size: 5.0 x 3.24 x 1.5 inches ? 3-year product warranty a type (except 5s) b type (except 5s)
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- note 1. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 2. hold-up time measured at 90% vout. 3. strongly recommend to conduct this test with dc voltage. if customer wishes to test with ac voltage, please disconnect all y-capacitors within arch power supply. derating block diagram
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- mechanical dimension ( top view ) standard (5s) pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 +dc out 5 -dc out assembly instructions *u case t=2.0mm customer is advised to screw into the threads no more than 2.0mm
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- mechanical dimension ( top view ) standard (12s 15s 24s 48s) pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 +dc out 5 +dc out 6 -dc out 7 -dc out a type (except 5s) b type (except 5s) pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 ~ 7 +dc out 8 ~ 11 -dc out pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 ~ 5 +dc out 6 ~ 7 -dc out assembly instructions *u case t=2.0mm customer is advised to screw into the threads no more than 2.0mm
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -5- efficiency versus load aqf120u-5s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 85.37 86.17 87.46 87.76 88.14 load (%) 10 20 30 40 50 115v (%) 69.59 81.53 83.15 84.92 85.96 230v (%) 73.66 81.49 85.04 86.21 87.16 load (%) 60 70 80 90 100 115v (%) 86.44 86.45 86.37 86.48 86.20 230v (%) 87.57 87.75 87.98 87.94 87.80 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v180v230v264v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqf120u-12s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 86.45 89.96 92 92.77 92.3 load (%) 10 20 30 40 50 115v (%) 73.62 82.98 86.43 88.26 89.27 230v (%) 71.83 81.82 86.81 89.54 90.58 load (%) 60 70 80 90 100 115v (%) 89.72 89.95 90.11 90.1 89.96 230v (%) 91.74 92.18 92.53 92.62 92.77 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -6- efficiency versus load aqf120u-15s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 86.03 88.78 90.06 90.45 90.75 load (%) 10 20 30 40 50 115v (%) 67.05 78.17 82.74 85.07 85.52 230v (%) 67.05 77.17 82.17 84.61 86.14 load (%) 60 70 80 90 100 115v (%) 87.40 88.34 88.44 88.67 88.78 230v (%) 87.39 88.68 89.5 90.14 90.45 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqf120u-24s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.78 91.27 93.11 93.52 93.81 load (%) 10 20 30 40 50 115v (%) 71.89 82.79 86.97 88.9 89.82 230v (%) 72.3 84.22 88.46 89.21 92.29 load (%) 60 70 80 90 100 115v (%) 90.54 90.78 91.13 91.4 91.27 230v (%) 92.14 92.86 93.14 93.44 93.52 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -7- efficiency versus load aqf120u-48s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.56 91.86 93.20 93.76 93.61 load (%) 10 20 30 40 50 115v (%) 74.99 83.9 87.25 89.17 90.01 230v (%) 67.31 79.29 84.97 88.18 89.99 load (%) 60 70 80 90 100 115v (%) 90.69 91.18 91.46 91.84 91.86 230v (%) 91.24 92.15 92.84 93.36 93.76 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
|