  Datasheet File OCR Text:
  diesel generator set mtu 4r0113 ds80 80 kwe / 60 hz / prime 208 - 600v reference mtu 4r0113 ds80 (80 kwe) for standby rating technical data system ratings prime voltage (l-l) 240v** 240v** 208v** 240v** 480v** 600v** phase 1 1 3 3 3 3 pf 1 1 0.8 0.8 0.8 0.8 hz 60 60 60 60 60 60 kw 80 80 80 80 80 80 kva 80 80 100 100 100 100 amps 333 333 278 241 120 96 skva@30% voltage dip 157 310 258 258 288 235 generator model 363csl1607 363csl1617 362csl1606 362csl1606 362csl1604 362psl1635 temp rise 105 c/40 c 105 c/40 c 105 c/40 c 105 c/40 c 105 c/40 c 105 c/40 c connection 12 lead zig-zag 4 lead 12 lead low wye 12 lead hi delta 12 lead hi wye 4 lead wye ** ul 2200 o ? ered // ? emissions ? epa tier 3 certi ed // ? generator set is designed and manufactured in facilities certi ed to standards iso 9001:2008 and iso 14001:2004 // ? seismic certification ? optional ? ibc certi cation ? oshpd pre-approval // ? ul 2200 / csa ? optional ? ul 2200 listed ? csa certi ed // ? performance assurance certification (pac) - generator set tested to iso 8528-5 for transient response - veri ed product design, quality and performance integrity - all engine systems are prototype and factory tested // ? power rating - accepts rated load in one step per nfpa 110 certifications and standards
2 // / ? / mtu 4r0113 ds80 (80 kwe) - prime // ? engine air cleaners oil pump oil drain extension & s/o valve full flow oil filter fuel filter with water separator jacket water pump thermostat blower fan & fan drive radiator - unit mounted electric starting motor - 12v governor ? electronic isochronous base - formed steel sae flywheel & bell housing charging alternator - 12v battery box & cables flexible fuel connectors flexible exhaust connection epa certi ed engine // ? generator nema mg1, ieee and ansi standards compliance for temperature rise and motor starting self-ventilated and drip-proof superior voltage waveform solid state, volts-per-hertz regulator 1% voltage regulation no load to full load brushless alternator with brushless pilot exciter 4 pole, rotating field 105 c maximum prime temperature rise 1 bearing, sealed flexible coupling full amortisseur windings 125% rotor balancing 3-phase voltage sensing 100% of rated load - one step 5% maximum total harmonic distortion // ? digital control panel(s) digital metering engine parameters generator protection functions engine protection sae j1939 engine ecu communications windows ? -based software multilingual capability remote communications to rdp-110 remote annunciator programmable input and output contacts ul recognized, csa certi ed, ce approved event recording ip 54 front panel rating with integrated gasket nfpa110 compatible standard equipment* // ? mtu onsite energy is a single source supplier // ? global product support // ? 2 year standard warranty // ? 4045hf285 diesel engine - 4.5 liter displacement - 4-cycle // ? engine-generator resilient mounted // ? complete range of accessories // ? generator - brushless, rotating field generator - 2/3 pitch windings - 300% short circuit capability with optional pmg // ? digital control panel(s) - ul recognized, csa certi ed, nfpa 110 - complete system metering - lcd display // ? cooling system - integral set-mounted - engine driven fan standard features* * represents standard product only. consult factory/mtu onsite energy distributor for additional con gurations.
3 // / ? / mtu 4r0113 ds80 (80 kwe) - prime // ? engine manufacturer john deere model 4045hf285 type 4-cycle arrangement 4-inline displacement: l (in 3 ) 4.5 (275) bore: cm (in) 10.6 (4.19) stroke: cm (in) 12.7 (5) compression ratio 19:1 rated rpm 1,800 engine governor jdec maximum power: kwm (bhp) 107 (144) speed regulation 0.25% air cleaner dry // ? liquid capacity (lubrication) total oil system: l (gal) 12 (3.2) engine jacket water capacity: l (gal) 12.5 (3.3) system coolant capacity: l (gal) 20.1 (5.3) // ? electrical electric volts dc 12 cold cranking amps under -17.8 c (0 f) 925 // ? fuel system fuel supply connection size 3/8? npt fuel return connection size 3/8? npt maximum fuel lift: m (ft) 2 (6.7) recommended fuel diesel #2 total fuel flow: l/hr (gal/hr) 74.6 (19.7) // ? fuel consumption at 100% of power rating: l/hr (gal/hr) 23.1 (6.1) at 75% of power rating: l/hr (gal/hr) 18.5 (4.9) at 50% of power rating: l/hr (gal/hr) 13.2 (3.5) // ? cooling - radiator system ambient capacity of radiator: c (f) 50 (122) maximum allowable static pressure on rad. exhaust: kpa (in. h 2 0) 0.12 (0.5) water pump capacity: l/min (gpm) 180 (48) heat rejection to coolant: kw (btum ) 56 (3,190) heat rejection to air to air: kw (btum ) 17.6 (1,002) heat radiated to ambient: kw (btum ) 10.5 (596) fan power: kw (hp) 6.5 (8.7) // ? air requirements aspirating: *m 3 /min (scfm) 7.7 (273) air flow required for rad. cooled unit: *m 3 /min (scfm) 187 (6,587) remote cooled applications; air flow required for dissipation of radiated gen-set heat for a max of 25 f rise: *m 3 / min (scfm) 38 (1,343) * air density = 1.184 kg/m 3 (0.0739 lbm/ft 3 ) // ? exhaust system gas temp. (stack): c (f) 560 (1,040) gas volume at stack temp: m 3 /min (cfm) 21.2 (750) maximum allowable back pressure: kpa (in. h 2 0) 7.5 (30) application data
4 // / ? / mtu 4r0113 ds80 (80 kwe) - prime ? mtu onsite energy. subject to alteration due to technological advances. oe 23 501 (77 3e) 2015-05 emissions data no x + nmhc co pm 3.97 0.72 0.08 all units are in g/hp-hr and shown at 100% load (not comparable to epa weighted cycle values). emission levels of the engine may vary with ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. the data was obtained in compliance with us epa regulations. the weighted cycle value (not shown) from each engine is guaranteed to be within the us epa standards. 5-mode emission data per 40 cfr 89 or 40 cfr 1039 (as applicable) is available upon request. rating definitions and conditions // ? prime power ratings apply to installations where utility power is unavailable or unreliable. at varying load, the number of generator set operating hours is unlimited. a 10% overload capacity is available for one hour in twelve. ratings are in accordance with iso 8528-1, overload power in accordance with iso 3046-1, bs 5514, and as 2789. average load factor: 75%. // ? deration factor: altitude : consult your local mtu onsite energy power generation distributor for altitude derations. temperature : consult your local mtu onsite energy power generation distributor for temperature derations. weights and dimensions drawing above for illustration purposes only, based on standard open power 480 volt generator set. lengths may vary with other voltages. do not use for installation design. see website for unit speci c template drawings. c/f = consult factory/mtu onsite energy distributor n/a = not available sound data is provided at 7 m (23 ft). generator set tested in accordance with iso 8528-10 and with in nite exhaust. weights and dimensions are based on open power units and are estimates only. consult the factory for accurate weights and dimen sions for your speci c generator set. sound data unit type prime full load level 0: open power unit db(a) 83.3 mtu onsite energy a rolls-royce power systems brand www.mtuonsiteenergy.com system dimensions (l x w x h) weight (less tank) open power unit (opu) 2,540 x 1,219 x 1,467 mm (100 x 48 x 57.75 in) 867 kg (1,912 lb)


▲Up To Search▲   

 
Price & Availability of MTU4R0113DS80

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X