AXIOM30HP www.axtal.com wasemweg 5 page 1(2) fon: +49 (6261) 939834 d-74821 mosbach fax: +49 (6261) 939836 germany e-mail: info@axtal.com gmbh & co. kg specification AXIOM30HP issue: 01 date: 2006-06-31 oscillator type : high-p erformance ocxo in co15 package parameter min. typ. max. unit condition frequency range mhz note 2 standard frequencies 10.000 mhz frequency stability ppm initial tolerance 20 ppb @v c = v ref /2 10% vs. temperature (steady state) 5 ppb operating temperature range -20 +70 c vs. supply voltage variation 0.5 ppb vs. load change 0.5 ppb long term (aging) per day 0.5 ppb/day @+40c, after 30 days long term (aging) 1 st year 30 ppb @+40c, after 30 days long term (aging) per 15 years after 500 ppb frequency adjustment range electronic frequency control (efc) 1 ppm efc voltage v c 0 2.5 5 v efc slope ( ? f / ? v c ) positive efc input impedance 100 k ? rf output signal waveform sinusoidal load 50 ? 10 % output level +5 +10 dbm harmonics -20 dbc warm-up time @25c 5 105 min ? f final /f 0 < 10 ppb phase noise -100 -130 -145 -150 -150 -150 dbc dbc dbc dbc dbc dbc @ 1hz @ 10 hz @ 100 hz @ 1 khz @ 10 khz @ 100 khz short term stability (allan variance) 510 -12 110 -11 110 -10 = 1 s = 10 s = 100 s reference voltage output 5.0 v oven alarm output (pin 2) low = alarm (not stable) high = ready 0 ? 0.4 v 2.4 ? 5 v oscillator enable input (pin 6) low = oscillator off high = oscillator on hcmos compatible supply voltage v s 11.4 12 12.6 v current consumption (steady state, @ +25c) 100 ma current consumption (warm-up) 340 ma storage temperature range -40 +85 c enclosure (see drawing) 20.5x20.5x12 max. mm iec 60679-3 co15-7 weight 10 gram packing palette iec 60286-3 esd sensitivity 1500 v hbm iec 61000-4-2 notes: 1. terminology and test conditions are according to iec standard iec60679-1, unless otherwise stated
AXIOM30HP www.axtal.com wasemweg 5 page 2(2) fon: +49 (6261) 939834 d-74821 mosbach fax: +49 (6261) 939836 germany e-mail: info@axtal.com gmbh & co. kg enclosure drawing: pin connections pin # symbol function 1 rf out rf output 2 oa oven alarm output 3 gnd ground 4 v ref reference voltage 5 v c control voltage (efc) 6 oe oscillator enable input 7 v s supply voltage environmental conditions test iec 60068 part ... iec 60679-1 clause ... test conditions visual inspection, dimensions 4.3 enclosure styles as in iec 60679-3 or 61837, if applicable sealing tests (if applicable) 2-17 4.6.2 gross leak: test qc, fine leak: test qk solderability resistance to soldering heat 2-20 2-58 4.6.3 test ta (235 5)c method 1 test tb method 1a, 5s shock* 2-27 4.6.8 test ea, 3 x per axes 100g, 6 ms half-sine pulse bump* 2-29 4.6.6 test eb, 4000 bumps per axes, 40g, 6 ms free fall* 2-32 4.6.9 test ed procedure 1, 2 drops from 1m height vibration, sinusoidal* 2-6 4.6.7 test fc, 30 min per axes, 10 hz - 55 hz 0,75mm; 55 hz - 2 khz, 10g rapid change of temperature 2-14 4.6.5 test na, 10 cy cles at extremes of operating temperature range dry heat 2-2 4.6.14 test ba, 16 h at upper temperature indicated by climatic category damp heat, cyclic* 2-30 4.6.15 test db variant 1 severity b), 55c/95% r.h., 6 cycles cold 2-1 4.6.16 test aa, 2 h at lower temperature indicated by climatic category climatic sequence* 1-7 4.6.17 sequence of 4.6.14, 4.6.15 (1 st cycle), 4.6.16, 4.6.15 (5 cycles) damp heat, steady state* 2-3 4.6.18 test ca, 56 days endurance tests - ageing - extended aging 4.7.1 4.7.2 30 days @ 85c, ocxo @25c 1000h, 2000h, 8000h @85c
|