Part Number Hot Search : 
2SC33 4730A TZM5233B BT2907 BJ120 3386P STPS10 F1066
Product Description
Full Text Search
 

To Download EDSX5-93H Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  features specifications functional speci cations service: liquid, gas, or vapour span, range and overrange limit: 1. unique hydroseal diaphragm permeation of hydrogen into the detecting unit through seal diaphragm can be suppressed thanks to the unique seal diaphragm (double coating) which employs coating of gold and ceramic. pressure transmitter hydroseal ? diaphragm version 2. high accuracy 0.15% accuracy for all calibrated spans is the standard feature for pressure transmitter covering 50 to 10000kpa (or 0.5 to 100 kgf/cm 2 ). fuji?s micro-capacitance silicon sensor assures this feature. 3. minimum environment in uence fuji?s patented ?advanced floating cell? design which protects the pressure sensor against changes in tempera- ture and overpressure substantially reduces total meas- urement error in actual ? eld applications. 4. fuji/hart bilingual communications protocol fcx?a iii series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart . any hart compatible devices can communicate with fcx?a iii . 5. application exibility various options that render the fcx?a iii series suitable for almost any process applications include. ? full range of hazardous location approvals ? 5-digit lcd meter with engineering unit ? stainless steel electronics housing ? built-in rfi ? lter and lightning arrester 6. burnout current exibility (under scale: 3.2 to 4.0ma, over scale: 20.0 to 22.5ma) burnout signal level is adjustable using model fxw hand held communicator ( hhc ) to comply with n a mur ne43. 7. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. process cover sensor unit ceramics coating gold coating sealing diaphragm coated with gold and ceramics base material (sus316l) micro capacitance silicone sensor remark: to minimize environmental in? uence, span should be greater than 1/40 of the max. span in most applications. ? lower range limit (vacuum limit) ; silicone ? ll sensor: see fig. 1 fluorinated ? ll sensor: 66kpa abs (500mmhg abs) at below 60c ? conversion factors to different units; 1 mpa=10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa =10mbar=101.9716mmh 2 o=4.01463inh 2 o output signal: 4 to 20ma dc with digital signal super- imposed on the 4 to 20ma signal. power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. 1. 5 (15) 9 (90) 15 (150) fkg 07 fkg 08 fkg 09 span limit [kpa] (bar) range limit [kpa] (bar) ?100 (?1) ?100 (?1) ?100 (?1) 500 (5) 3000 (30) 10000 (100) upper limit lower limit ?0.1 to 0.5 (?1 to 5) ?0.1 to 3 (?1 to 30) ?0.1 to 10 (?1 to 100) 50 (0.5) 300 (3) 1000 (10) 500 (5) 3000 (30) 10000 (100) static pressure [mpa] (kgf/cm 2 ) over range lemit [mpa] (bar) type max. min. data sheet fkg ... 5 EDSX5-93H aug. 10, 2011 date [ l-type ] [ t-type ]
2 fkg ... 5 (note) (1) hhc: hand held communicator load limitations: see ? gure below 2000 [ ] 1500 1000 load resistance 500 250 0 1474 577 operating area 24v 45v 10 16.35 50 e[ v ] 10.5v power voltage (dc) r= e-10.5 (imax+0.9)x10 -3 note: for communication with hhc (1) (model: fxw), min. of 250 ?? required. hazardous locations: (under an application) see table 2 zero/span adjustment : zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw. damping: adjustable from hhc or local con? gurator unit with lcd display. the time constant is adjustable bet ween 0.06 to 32 seconds. zero elevation/suppression: zero can be elevated or suppressed within the speci? ed range limit of each sensor model. normal/reverse action: selectable from hhc (1) . indication: analog indicator or 5-digit lcd meter, as speci? ed. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?output hold?, ?output overscale? or ?output underscale? modes. ?output hold?: output signal is hold as the value just before failure happens. ?output overscale?: adjustable within the range 20.0ma to 22.5ma from hhc (1) ?output underscale?: adjustable within the range 3.2ma to 4.0ma from hhc (1) 3.2 4 20 22.5 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout loop-check output: transmitter can be con? gured to provide constant signal 3.2ma through 22.5ma by hhc. temperature limit : ambient: ?40 to +85c (?20 to +80c for lcd indicator) (?40 to +60c for arrester option) (?10 to +60c for ? uorinated oil ? ll transmitter) for explosionproof units (? ameproof or intrinsic safety), ambient tempera- ture must be within the limits speci- ? ed by each standard. process: ?40 to +100c for silicone ? ll sensor ?20 to +80c for fluorinated oil fill sensor storage: ?40 to +90c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following items can be remotely displayed or con? gured. note: hhc?s version must be higher than 7.0 (or fxw 1? 4), for fcx -a iii . local con gurator with lcd display (option): local con? gurator with 3 push button and lcd display can support following items. items by communication with fxw by local con? gurator (with 3 push button) display set display set tag no. vvvv model no. vvvv serial no. & software version v ? v ? engineering unit vvvv range limit v ? v ? measuring range vvvv damping vvvv output mode v ? v ? burnout direction vvvv calibration vvvv output adjust ? v ? v data v ? v ? self diagnoses v ? v ? printer (in case of fxw with printer option) v ??? external switch lock vvvv transmitter display vvvv linearize vv ?? rerange vvvv saturate current vvvv write protect vvvv history ? calibration history ? ambient temperature history v v v ? v v v ? emc conformity: en61326-1: 2006 performance speci cations reference conditions, silicone oil ? ll, 316ss isolating diaphragms, 4 to 20ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability) stability: 0.15% of upper range limit (url) for 10 years.
3 mounting: on 60.5mm (jis 50a) pipe using mount- ing bracket, direct wall mounting, or direct process mounting. mass {weight}: transmitter approximately 3.4kg without options. add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option optional features indicator: a plug-in analog indicator (2.5% accu- racy). an optional 5-digit lcd meter with engi- neering is also available. local con gurator with lcd display: an optional 5 digits lcd meter with 3 push buttons can support items as using communication with fxw. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity : 4kv (1.2 50s) oxygen service: special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. the ? ll ? uid is ? uorinated oil. chlorine service: the ? ll ? uid is ? uorinated oil. degreasing: process-wetted parts are cleaned, but the ? ll ? uid is standard silicone oil. not for use on oxygen or chlorine measurement. nace speci cation: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. astm b7m or l7m bolts and 2hm nuts (class ii) are standard. vacuum service: special silicone oil and ? lling procedure are applied. see fig.1. optional tag plate: an extra stainless steel tag with customer tag data is wired to the transmitter. coating of cell: cell?s surface is finished with epoxy/ polyurethane double coating. specify if environment is extermely corrosive. temperature effect: effects per 28c change between the limits of ?40c and +85c zero shift: (0.1+0.075 )% /28c total effect: (0.125+0.075 )%/28c overrange effect: zero shift; 0.4% of url for any overrange to maximum limit supply voltage effect: less than 0.005% of calibrated span per 1v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and ? eld strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) update period: 60 msec step response: time constant: 0.08s dead time: 0.12s (without electrical damping) mounting position effect: zero shift, less than 0.1kpa {1m bar} for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. dielectric strength: 500v ac, 50/60hz 1 min., between cir- cuit and earth. insulation resistance: more than 100m ? at 500v dc. internal resistance for external eld indicator: 12 ? or less physical speci cations electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 1.5 conduit, as speci? ed. process connections: 1 /4 -18 npt or rc 1 /4 on 54mm centers, as speci? ed. meet din 19213 process-wetted parts material: material code process cover wetted sensor body vent/drain diaphragm other wetted parts c 316 stainless steel (*1) 316l stainless steel (*2) 316 stainless steel 316/316l stain- less steel notes: (* 1 ) scs14a per jis g 5121 (equivalent cf8m per astm a351/a351m) (* 2 ) the diaphragm face is coated with gold and ce- ramic. remark: sensor o-rings : viton o-ring and te? on gasket select- able non-wetted parts material: electronics housing: low copper die-cast aluminum alloy ? nished with epoxy/ polyurethane double coating (stan- dard), or 316 stainless steel (scs14a per jis g5121), as speci? ed. bolts and nuts: cr-mo alloy (standard), or 304 stainless steel. fill ? uid: silicone oil (standard) or ? uori- nated oil mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p url span url span fig. 1 relation between process temperature and operating pressure ?40 60 ?15 85 100 none-operating area 2.7 {27} 4 {40} 20 operating pressure process temperature[c ] {200} 101 {1010} [kpa abs] {mbar abs} silicone oil (code:y,g,n) operating area
4 fkg ... 5 code symbols description note note 1 note 5 note 8 note 8 note 7 note 7 note 7 note 8 digit 4 4567 123 f0 5 kg 89 10 11 12 13 14 15 21 digit no. of code 5 6 7 8 9 s t v w x process connection rc 1 /4 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt rc 1 /4 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt oval flange screw 7 /16 -20unf 7 /16 -20unf m10 m10 7 /16 -20unf 7 /16 -20unf 7 /16 -20unf m10 m10 7 /16 -20unf conduit connection g 1 /2 1 /2 -14npt pg13.5 m201.5 pg13.5 g 1 /2 1 /2 -14npt pg13.5 m201.5 pg13.5 case type t type t type t type t type t type l type l type l type l type l type note 1: (*1) the diaphram face is coated with gold and ceramic. 50 500 (or 0.55) 300 3000 (or 330) 1000 10000 (or 10100) process wetted cell body cover diaphragm other wetted parts 316 stainless steel 316 stainless steel (*1) 316 stainless steel 6 7 7 8 9 c 9 indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes digital, 0 to 100% linear scale none digital, custom scale none digital, 0 to 100% linear scale yes digital, custom scale yes digital, 0 to 100% linear scale (local configurator unit with lcd display) none digital, custom scale (local configurator unit with lcd display) none digital, 0 to 100% linear scale (local configurator unit with lcd display) yes digital, custom scale (local configurator unit with lcd display) yes a b d e f h l p q s 1 2 4 5 11 vent/drain mounting bracket process connection standard none standard standard yes, sus304 standard standard yes, sus316 standard side none standard side yes, sus304 standard side yes, sus316 standard a c k d f l 10 none (for ordinary locations) tiis, flameproof (cable gland seal) (*5) tiis, intrisic safety fm, flameproof (or explosionproof) (*8) fm, instrisic safety and nonincentive fm combined of flameproof and intrisic safety (*8) atex flameproof (*7) atex intrisic safety atex type n atex combined of flameproof and intrinsic safety (*7) iecex scheme, flameproof (*7) iecex scheme, intrisic safety csa, flameproof (or explosionproof) (*8) csa, intrisic safety and nonincentive nepsi, flameproof (or explosionproof) nepsi, intrisic safety nepsi, combined of flameproof and intrisic safety a c g d h v x k p m r t e j f s u
5 description note note 2 note 9 note 9 note 3 note 4 digit 12 13 14 15 21 extra ss tag plate stainless steel elec. housing coating of cell none none none yes none none none none yes yes none yes none yes yes yes yes yes treatment fill fluid standard silicone oil standard fluorinated oil degreasing silicone oil oxygen service fluorinated oil nace specification silicone oil ( not available for 15th digit code "a", "b" ) teflon (gasket) (*4) cr-mo alloy hexagon socket head cap screw/carbon steel nut cr-mo alloy hexagon bolt/nut nace bolt/nut (astm a193 b7m/a194 2hm) nace bolt/nut (astm a320 l7m/a194 2hm) 304 stainless steel bolt/304 stainless steel nut 316 stainless steel bolt/316 stainless steel nut (*3) instruction manual unattached opposite vent/drain plug position instruction manual attached opposite vent/drain plug position instruction manual unattached 4567 123 f05 kg 89 10 11 12 13 14 15 21 digit no. of code y b m n p q y w g a n a b c d e u b l c p note2: (*2) costomer tag number can be engraved on standartd stainless steel name plate. if extra tag plate is required, select "yes". note3: (*3) if other option is not necessary, 21st digit code is blank. in case of 21st digit code is blank, instruction manual attached. note4: (*4) in case of tropical use, select stainless bolts and nuts. note5: (*5) available for 4th digit code "s". note7: (*7) available for 4th digit code "6", "8", "t", "w". note8: (*8) available for 4th digit code "6", "t". note9: (*9) not available for 10th digit code "c". (*2)  vent drain plug type standard standard standard standard standard standard (*9) accessories oval flanges: (model ffp, refer to data sheet no. eds6-128) converts process connection to 1 /2 -14 npt or to rc 1 /2 ; in carbon steel or in 316 stainless steel. hand-held communicator: (model fxw, refer to data sheet no. eds8-47) ordering information when ordering this instrument, specify. 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormality is occured in the transmitter. hold / underscale / overscale unless otherwise speci? ed, output hold function is sup- plied. 4. indication method (indicated value and unit) in case of the actual scale (code d,h,p,s on 9th digit). 5. tag no. (up to 14 alphanumerical characters), if required.
6 fkg ... 5 outline diagram (unit:mm) 4&&5"#-& 4&&5"#-& uiejhjupguif dpeftzncpmt 4 (   3d %&' ) 6/' 4$3&8%&15) $poevjudpoo 1sfttdpoo 0wbmgsbohftdsfx %&5"*-" 13&44$0//
%&5"*-# $0/%6*5$0//
5"#-&  )      ' & % 5 /15   #% ) 6/' 4$3&8%&15) 7 1h   #% ) . 4$3&8%&15) 8 .   #% ) . 4$3&8%&15) 9 1h   #% ) 6/' 4$3&8%&15) */$"4&0'5)%*(*5$0%&5 */$"4&0'5)%*(*5$0%&4 7 8 9 ;&30"%+4$3&8 "13&44$0// .5(1*1&+*4" #
)0-&4%*" 6#0-5. 7&/5%3"*/1-6( #$0/%6*5$0// &"35)5&3.*/"- 07"-'-"/(&4$3&8 4&&5"#-& )1 -1 . 7&/5%3"*/1-6( 8)&/5)&7&/5%3"*/1-6( "55"$)&%0/5)&611&34*%& 0'5)&%&5&$503
/05&
                       4*%&7&/5 015*0/
 8*5)"/"-0(*/% 
8*5)%*(*5"-*/% 
/05&
5)&13&4463&$0//&$503*4-0$"5&%0/5)&%08/4*%&  463'"$&0'5)&%&5&$503 8)&/5)&7&/5%3"*/1-6(*4  "55"$)&%0/5)&611&34*%&0'5)&%&5&$503  8)&/5)&45%*(*50'5)&$0%&4:.#0-4$ 1
 /05&
*/$"4&0'5)$0%& ?$? $"#-&*446*5#-& ( %&5"*-l$z    ( 015*0/1"354'03'-".&1300'0'5**4 +"1"/
uiejhjudpef$ $bcmfhmboeuzqf
 /05&
$"#-&(-"/%    $$0/%6*5$0// 445"(1-"5& $0//&$5*0/%*"(3". $, $,  
7 7&/5%3"*/1-6( 8)&/5)&7&/5%3"*/1-6( "55"$)&%0/5)&611&34*%& 0'5)&%&5&$503
/05&
"13&44$0// .5(1*1&+*4" #
7&/5%3"*/1-6( &"35)5&3.*/"- 07"-'-"/(&4$3&8 4&&5"#-& )1 -1 . ;&30"%+4$3&8 */$"4&0'5)%*(*5$0%& */$"4&0'5)%*(*5$0%&    8*5)"/"-0(*/% 8*5)%*(*5"-*/%            

        4&&5"#-& uiejhjupguif dpeftzncpmt  (   3d %&' ) 6/' 4$3&8%&15) $poevjudpoo 1sfttdpoo 0wbmgsbohftdsfx %&5"*-# $0/%6*5$0//
5"#-&   ' & %  /15   #% ) 6/' 4$3&8%&15)  1h   #% ) . 4$3&8%&15)  .   #% ) . 4$3&8%&15)  1h   #% ) 6/' 4$3&8%&15) 4&&5"#-& %&5"*-" 13&44$0//
 )    4*%&7&/5 015*0/
 #$0/%6*5$0// )0-&4%*" 6#0-5. /05&
5)&13&4463&$0//&$503*4-0$"5&%0/5)&%08/4*%&  463'"$&0'5)&%&5&$503 8)&/5)&7&/5%3"*/1-6(*4  "55"$)&%0/5)&611&34*%&0'5)&%&5&$503  8)&/5)&45%*(*50'5)&$0%&4:.#0-4$ 1
 445"(1-"5& $0//&$5*0/%*"(3". $, $,  
printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ information in this catalog is subject to change without notice. fkg ... 5 atex ex ii 3 gd eex nl iic t5 tamb = ?40c to +50c eex nl iic t4 tamb = ?40c to +70c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=25.18nf, li=0.694mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh eex nal iic t5 tamb = ?40c to +50c eex nal iic t4 tamb = ?40c to +70c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual (pending) class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, ci=25.18nf (without arrester), ci=35.98nf (with arrester), li=0.694mh authorities type n nonincendive model code 9th digit 13th digit a,b,d y,g,n ?40c to +85c l,p,1,2 y,g,n ?20c to +80c q,s,4,5 y,g,n ?20c to +60c e,f,h y,g,n ?40c to +60c C w,a ?10c to +60c tamb atex ex ii 2 gd ex d iic t6 ip66/67 t85c tamb = ?40c to +65c ex d iic t5 ip66/67 t100c tamb = ?40c to +85c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60c csa class i div.1 groups c, d class ii div.1 groups e, f, g class iii div.1 note) seal not required enclosure is allowed. tiis ex do iib+h 2 t4 tamb max = +60c maximum process temp. = +120c iecex scheme ex d iic t5 ip66/67 tamb = ?40c to +85c ex d iic t6 ip66/67 tamb = ?40c to +65c authorities flameproof nepsi ex d iib+h 2 t6 tamb = ?40c to +60c atex ex ii 1 g ex ia iic t5 tamb = C40c to +50c ex ia iic t4 tamb = C40c to +70c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=28v, imax=94.3ma, pi=0.66w, ci=35.98nf, li=0.694mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, imax=94.3ma, ci=25nf (without arrester), ci=36nf (with arrester), li=0.6mh (without analog meter), li=0.7mh (with analog meter) tiis ex ia iic t4 tamb max = +60c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=38.4nf, li=0.694mh iecex scheme ex ia iic t4 tamb = C40c to +70c ex ia iic t5 tamb = C40c to +50c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) authorities intrinsic safety model code 9th digit 13th digit a,b,d y,g,n ?40c to +85c l,p,1,2 y,g,n ?20c to +80c q,s,4,5 y,g,n ?20c to +60c e,f,h y,g,n ?40c to +60c C w,a ?10c to +60c tamb nepsi ex ia iic t4 ex d iib+h 2 t6 / ex ia iic t4 entity parameters: ui=42.4v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh model code 9th digit 13th digit a,b,d y,g,n ?40c to +85c l,p,1,2 y,g,n ?20c to +80c q,s,4,5 y,g,n ?20c to +60c e,f,h y,g,n ?40c to +60c C w,a ?10c to +60c tamb table 2


▲Up To Search▲   

 
Price & Availability of EDSX5-93H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X