16/12/2010 undk 09 (with beam columnator, rs232) 1 ultrasonic distance measuring sensors ultrasonic sensors www.baumer.com general data scanning range sd 3 ... 150 mm scanning range close limit sdc 3 ... 150 mm scanning range far limit sde 3 ... 150 mm repeat accuracy < 0,5 mm repeat accuracy (flter active) < 0,1 mm resolution < 0,3 mm resolution (flter active) < 0,1 mm sonic frequency 380 khz response time ton < 7 ms alignment aid target indication fashing light indicator yellow led / red led temperature drift < 2 % of distance to target so electrical data voltage supply range +vs 15 ... 30 vdc current consumption max. 35 ma output circuit rs 232 baud rate 115200 residual ripple < 10 % vs short circuit protection yes reverse polarity protection yes, vs to gnd mechanical data type rectangular housing material pa 12 material (beam columnator) pom width / diameter 8,6 mm height / length 48,8 mm depth 57,7 mm ambient conditions operating temperature 0 ... +60 c protection class ip 67 order reference connection types undk 09t9114/d1 cable pur 4 x 0,08, 2 m undk 09t9114/ks35ad1 fylead connector m8, l=200 mm sample picture sample drawing 48 ,8 48 15 15 2, 95 30 20 ,5 33, 2 57, 7 23, 6 24, 5 3 , 2 ( 2 x ) 8, 6 m3 (3x) 10 ,2 19 ,9 6, 5 14, 5 8, 2 3 , 5 ( 2 x ) 2 , 5 ( 4 x ) 3 , 2 17 ,4 3, 25 36 ,7 5 3 , 2 ( 2 x ) 8, 6
|