data sheet no. pd10042-e series pvt322 microelectronic power ic hexfet ? power mosfet photovoltaic relay dual pole, normally open 0-250v, 170ma ac/dc (hexfet is the registered trademark for international rectifier power mosfets) general description the pvt322 series photovoltaic relay is a dual- pole, normally open solid-state relay that can re- place electromechanical relays in many applications. it utilizes international rectifier?s hexfet power mosfet as the output switch, driven by an inte- grated circuit photovoltaic generator of novel con- struction. the output switch is controlled by radia- tion from a gaalas light emitting diode (led) which is optically isolated from the photovoltaic generator. series pvt322 relays are packaged in an 8-pin, molded dip package with either thru-hole or sur- face mount (gull-wing) terminals. it is available in standard plastic shipping tubes or on tape-and- reel. please refer to part identification information opposite. applications on/off hook switch tip and ring line switching general switching part identification pvt322 th ru-hole pvt322s smt PVT322S-T smt, t&r features hexfet power mosfet output bounce-free operation 4,000 v rms i/o isolation linear ac/dc operation solid-state reliability ul recognized and babt certified
series pvt322 2 www.irf.com electrical specifications (-40c t a +85c unless otherwise specified ) input characteristics limits units minimum control current (see figure1) 2.0 ma maximum control current for off-state resistance @ta=+25c 0.4 ma control current range (caution: current limit input led, see figure 5) 2.0 to 25 ma maximum reverse voltage 7.0 v connection diagram general characteristics limits units minimum dielectric strength, input-output 4000 v rms minimum dielectric strength, pole-to-pole 1000 v dc minimum insulation resistance, input-output, @t a =+25c, 50%rh, 100v dc 10 12 ? maximum capacitance, input-output 1.0 pf maximum pin soldering temperature (10 seconds maximum) +260 ambient temperature range: operating -40 to +85 c storage -40 to +100 output characteristics limits units operating voltage range 0 to 250 v (dc or ac peak) maximum load current @ t a =+40c 5ma control (see figure 1) (single and dual channel operation) 170 ma maximum peak load current (10ms maximum duration) (single and dual channel operation) 500 ma maximum on-state resistance @t a =+25c for 50ma pulsed load, 5ma control (see figure 3) 10 ? maximum off-state leakage @t a =+25c, 250v (see figure 4) 1.0 a maximum turn-on time @t a =+25c (see figure 6) 3.0 ms for 50ma, 100 v dc load, 5ma control maximum turn-off time @t a =+25c (see figure 6) 0.5 ms for 50ma, 100 v dc load, 5ma control maximum output capacitance @ 50v dc 50 pf international rectifier does not recommend the use of this product in aerospace, avionics, military or life sup- port applica tions. users of this international rectifier product in such applications assume all risks of such use and indemnify international rectifier against all dam- ages resulting from such use.
series pvt322 www.irf.com 3 figure 3. typical normalized on-resistance 0.5 1.0 1.5 2.0 2.5 -0.5 -1.0 -1.5 -2.0 -2.5 -50 -100 -150 -200 50 100 150 200 250 -250 3.0 -3.0 figure 2. linearity characteristics 20 40 60 80 100 0 0 100 200 150 50 figure 1. typical current derating curve figure 4. typical normalized off-state l eakage 2 ma i led = 5 ma
series pvt322 4 www.irf.com figure 7. delay time definitions figure 8. typical output capacitance figure 5. input characteristics (current controlled) figure 6. typical delay times led current (ma) delay time (milliseconds)
series pvt322 www.irf.com 5 ir world headquarters: 233 kansas st., el segundo, california 90245 tel: (310) 252-7105 data and specifications subject to change without notice. 10/17/2003 case outlines 01-2030 01 01-2031 01
|