|
|
|
Philips
|
Part No. |
74HC181U 74HCT181U
|
OCR Text |
...g words provides 16 arithmetic operations: add, subtract, compare, double, plus 12 others provides all 16 logic operations of two variables: exclusive-or, compare, and, nand, nor, or plus 10 other logic operations output capability: stan... |
Description |
4-bit arithmetic logic unit
|
File Size |
167.38K /
20 Page |
View
it Online |
Download Datasheet |
|
|
|
ST Microelectronics
|
Part No. |
M30W0R7000B1
|
OCR Text |
...top or bottom location) dual operations ? program erase in one bank while read in others ? no delay between read and write operations block locking ? all blocks locked at power up ? any combination of blocks can be locked ?wp for blo... |
Description |
128 Mbit (8Mb x 16, Multiple Bank, Burst) 1.8V Supply Flash Memory
|
File Size |
559.06K /
87 Page |
View
it Online |
Download Datasheet |
|
|
|
Cypress
|
Part No. |
CY7C1393KV18-333BZI CY7C1393KV18-300BZXC
|
OCR Text |
...as data outputs to support read operations and the write port has data inputs to support write operations. the ddr ii sio has separate data inputs and data outputs to completely eliminate the need to ?turnaround? the data bus required with ... |
Description |
18-Mbit DDR II SIO SRAM Two-Word Burst Architecture
|
File Size |
594.65K /
30 Page |
View
it Online |
Download Datasheet |
|
|
|
Global Components & Controls
|
Part No. |
G903AO-DC12 G903AO-DC110 G903AO-DC110-2 G903AO-DC12-2 G903AO-DC18 G903AO-DC18-2 G903AO-DC24 G903AO-DC24-2 G903AO-DC48 G903AO-DC48-2 G903AO-DC5 G903AO-DC5-2 G903AO-DC6 G903AO-DC6-2 G903AO-DC9 G903AO-DC9-2
|
OCR Text |
...lectrical life: 5 x 10 operations (typical) 0.5 x 10 opeations @ 16a, 277vac/24vdc, resistive 0.2 x 10 operations @ 20a, 277vac/24vdc, resistive 0.25 x 1... |
Description |
Relay. Coil voltage 12 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 110 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 110 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F. Relay. Coil voltage 12 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F. Relay. Coil voltage 18 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 18 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F. Relay. Coil voltage 24 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 24 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F. Relay. Coil voltage 48 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 48 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F. Relay. Coil voltage 5 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 5 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F. Relay. Coil voltage 6 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 6 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F. Relay. Coil voltage 9 VDC. Contact arrangement 1A. Cover open frame. Insulation class B. Relay. Coil voltage 9 VDC. Contact arrangement 1A. Cover: open frame. Insulation class F.
|
File Size |
36.57K /
2 Page |
View
it Online |
Download Datasheet |
|
Price and Availability
|